Call us:86-0731-84139855
Language

中文 English

/upload/2017-04/02/product.jpg
Current location:Home> Products> Chromatography> HPLC

LC600A Isocratic High Performance Liquid Chromatography

Isocratic system with P600 high-pressure constant-current pump and UV600 detector. Its can control numbers of P600 pumps, UV600 detectors, constant-temperature column ovens and so on. Having the function of varied high-pressure elution and wavelength scan.


Specifications:



 LC-P600 High-pressure Pump

 Flow Rate Range  0.001-9.999mL/min  in 0.001mL/min increments
 Pressure Range  Error≤0.5MPa0-42MPa
 Flow Rate Precision  RSD0.06%
 Pulsation  ≤0.1MpaFlow Rate 1ml/minPressure 5-10Mpa
 Qualitative Analysis  RSD6≤0.1%Naphthalene Methyl Alcohol Solvent
Quantitative Repeatability

RSD6≤0.3%Naphthalene Methyl Alcohol Solvent

 Flow Rate Setting Error  Ss≤2%1mL/min water, 5-10MPa room temperature
 Air Tightness of Pump  Pressure 42MPa, time 10min, Pressure Drop0.5MPa    
 Mixing Accuracy  ±1%
 Mixing Precision  ±0.2%
 Size  450mm x 300mm x 160mm(W*H*D)

 LC600-UV600 Detector

 Wavelength Range  190-680nm
 Flow Cell  8μL
 Spectrum Band Width  8nm
 Baseline noise  ≤±0.25 x 10-5AUEmpty Cell
 Wavelength Accuracy  ±1nm
 Baseline drift  ≤0.4 x 10-4AUEmpty Cell
 Wavelength Precision  <0.1nm
 Limit of Detection  3 x 10-9g/mLNaphthalene Methyl Alcohol Solvent
 Size  450mm x 300mm x 160mm(W*H*D)

 

Description:




1. LC-P600  High-pressure and Constant-current Pump

1) Reciprocating parallel pump, flow rate precision, small pulsation, extending the operational life for the gasket ring and piston rod.

2) Pressure pulsation is controlled by diaphragmatic damper in seconds and electronic pulse suppression technique at the same time to ensure the limit baseline noise.

3) Single-side valve all day, simple structure, good air tightness

4) Automatic retracting piston rods, easy to change the gasket ring.

5) Can choose the automatic washing function for the column, and it’s adapt for the analysis condition which using buffer salt.

2LC600-UV600   UV Detector

1). Parallel dual-cone holes flow cell, eliminating the noise and making efficient detection.

2). Boot auto-detection. Estimating the error accuracy of wavelength through the position of 486.6nm and 656nm on the chromatogram map, to ensure the wavelength precision and the best status for the instrument.

3). Using multi-microprocessor to control circuit, which can manage signal acquisition, data processing, system control and communication. Its can set the wavelength, filtering wavelength constant, output value and runtime through LCD and 7 function keys conveniently when you are doing the isocratic analysis. Also have the function of deuterium lamp switch, spectrum scan and starting analysis procedure.

4). Full digital switching system, to avoid the disturbance based on the multi digital - to - analog conversion for the chromatographic signal

 

Application Area

chemical analysispoison analysisenvironmental analysisprotein food detectionmedicine testingpolymer analysis.

 

InquiryPlease feel free to submit your inquiry information to us. We will contact with you as soon as possible.

  • Name:

    Country:

  • * Email:
  • Tel:
  • Company:
  • * Inquiry:

Sales Contact